Self-Regulating Heating Cable
– “Tech-Heater”
About Tech-Heater
About Tech-Heater
Product Futures
Product Futures
Self-regulating system
Self-regulating system

World’s First, Made in Japan
World’s First, Made in Japan
Applicable for industrial, residential, and commercial use, TECHEATER® offers a wide range of tailor-designed solutions.
We provide customization, consultations, and proposals to meet diverse customer needs.
Feature 1: High Energy Efficiency
Feature 1: High Energy Efficiency
As the temperature rises, electrical resistance increases and reduces the current flow; when the temperature drops, the resistance decreases, allowing more current to flow.
This mechanism reduces power consumption and delivers high energy efficiency.

PTC ceramics exhibit a characteristic in which their electrical resistance increases as the temperature rises.
Future 2: Safety
Future 2: Safety
Even without a thermostat, the heater will not undergo abnormal temperature rise or burnout.
It also does not overheat when heater sections come into contact, allowing installation with overlapping layers.

Feature 3: High Flexibility
Feature 3: High Flexibility
The cable is highly flexible, making it easy to install around steps, complex piping, and fittings.
There are both 100V and 200V specifications.
The 100V model is equipped with a power plug, allowing it to be used simply by plugging it into a standard household power outlet.

Feature 4: Adjustable Length
Feature 4: Adjustable Length
*Such modifications are difficult with general heating wires.
*Installation and processing must be performed by a certified electrician.
*A dedicated insulation and sealing kit is required for installation.

Future 5: Diverse Applications
Future 5: Diverse Applications
Thanks to its soft and flexible structure, TECHHEATER® can be adapted to a wide variety of applications.
We provide design and installation services to meet your needs. Please feel free to contact us for consultation.

Roof top

Direct Attachment

Sheet Type (Custom-Made)
Also Suitable for Concrete Curing Applications

Direct Winding

Panel Type(Custom-Made)

Buried Underground
Although it is rarely visible, it is widely used in a variety of applications, including highways, railways, and food processing plants.

Tunnel Snow-Melting

Roof De-Icing and Icicle Prevention

Railway Snow Accumulation and Freezing Prevention

Pipe Heat Retention, Heating, and Freeze Protection

Plant Thermal Insulation, Heating, and Solidification Prevention

Container Thermal Control
Future 6: High Durability
Future 6: High Durability
As a result, it does not deteriorate under heat or voltage stress, ensuring an exceptionally long service life. It could operate for over ten years without any issues.
The outer sheath is also both flexible and extremely robust, contributing to the heater’s long-lasting performance.
With its outstanding durability, TECHHEATER® delivers excellent cost performance over the long term.

Comparison with Other Heaters
Comparison with Other Heaters
Tech-Heater – Panel Heater Application
Tech-Heater – Panel Heater Application
お気軽にご相談ください。
Specification
Specification



Classification of Standard Products
Classification of Standard Products
- For General Users
(For 100V with 1 m power cord, plug included) - This model can be used simply by plugging it into a household power outlet.
- For Professional Use
(For 200V with 1 m power cord, no plug) - This model is for professional use and requires electrical installation work.
- Bulk cable
(Compatible with both 100V and 200V, with 1 m power cord, no plug) - This is a long-length model. This model is for professional use and requires electrical installation work.
The heater length can be extended up to 50 m.
Please feel free to contact us for further consultation.
Techheater Specification
Techheater Specification
T6 Series – 100V
Maximum heating element temperature: 65°C
Maximum cable surface temperature: approx. 45°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T6 Series – 100V
Maximum heating element temperature: 65°C
Maximum cable surface temperature: approx. 45°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W) | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T6-10-P01 | 1 | 16 | 13 | 11 | 75 | -30℃~60℃ |
| T6-10-P02 | 2 | 32 | 26 | 22 | 75 | |
| T6-10-P03 | 3 | 48 | 39 | 33 | 75 | |
| T6-10-P05 | 5 | 80 | 65 | 55 | 75 | |
| T6-10-P10 | 10 | 160 | 130 | 110 | 75 | |
| T6-20-P01 | 1 | 20 | 16 | 12 | 50 | |
| T6-20-P02 | 2 | 40 | 32 | 24 | 50 | |
| T6-20-P03 | 3 | 60 | 48 | 36 | 50 | |
| T6-20-P05 | 5 | 100 | 80 | 60 | 50 | |
| T6-20-P10 | 10 | 200 | 160 | 120 | 50 | |
| T6-30-P01 | 1 | 29 | 23 | 18 | 35 | |
| T6-30-P02 | 2 | 58 | 46 | 36 | 35 | |
| T6-30-P03 | 3 | 87 | 69 | 54 | 35 | |
| T6-30-P05 | 5 | 145 | 115 | 90 | 35 | |
| T6-30-P10 | 10 | 290 | 230 | 180 |
35 | |
T6 Series – 200V
Maximum heating element temperature: 65°C
Maximum cable surface temperature: approx. 45°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T6 Series – 200V
Maximum heating element temperature: 65°C
Maximum cable surface temperature: approx. 45°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W) | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T6-10-01 | 1 | 22 | 18 | 15 | 75 | -30℃~60℃ |
| T6-10-02 | 2 | 44 | 36 | 30 | 75 | |
| T6-10-03 | 3 | 66 | 54 | 45 | 75 | |
| T6-10-05 | 5 | 110 | 90 | 75 | 75 | |
| T6-10-10 | 10 | 220 | 180 | 150 | 75 | |
| T6-20-01 | 1 | 27 | 23 | 18 | 50 | |
| T6-20-02 | 2 | 54 | 46 | 36 | 50 | |
| T6-20-03 | 3 | 81 | 69 | 54 | 50 | |
| T6-20-05 | 5 | 135 | 115 | 90 | 50 | |
| T6-20-10 | 10 | 270 | 230 | 180 | 50 | |
| T6-30-01 | 1 | 35 | 29 | 23 | 35 | |
| T6-30-02 | 2 | 70 | 58 | 46 | 35 | |
| T6-30-03 | 3 | 105 | 87 | 69 | 35 | |
| T6-30-05 | 5 | 175 | 145 | 115 | 35 | |
| T6-30-10 | 10 | 350 | 290 | 230 | 35 | |
T9 Series – 100V
Maximum heating element temperature: 95°C
Maximum cable surface temperature: approx. 70°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T9 Series – 100V
Maximum heating element temperature: 95°C
Maximum cable surface temperature: approx. 70°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W) | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T9-20-P01 | 1 | 19 | 18 | 17 | 50 | -20℃~100℃ |
| T9-20-P02 | 2 | 38 | 36 | 34 | 50 | |
| T9-20-P03 | 3 | 57 | 54 | 51 | 50 | |
| T9-20-P05 | 5 | 95 | 90 | 85 | 50 | |
| T9-20-P10 | 10 | 190 | 180 | 170 | 50 | |
| T9-30-P01 | 1 | 28 | 27 | 24 | 35 | |
| T9-30-P02 | 2 | 56 | 54 | 48 | 35 | |
| T9-30-P03 | 3 | 84 | 81 | 72 | 35 | |
| T9-30-P05 | 5 | 140 | 135 | 120 | 35 | |
| T9-30-P10 | 10 | 280 | 270 | 240 | 35 | |
T9 Series – 200V
Maximum heating element temperature: 95°C
Maximum cable surface temperature: approx. 70°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T9 Series – 200V
Maximum heating element temperature: 95°C
Maximum cable surface temperature: approx. 70°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W) | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T9-20-01 | 1 | 36 | 30 | 25 | 50 | -20℃~100℃ |
| T9-20-02 | 2 | 72 | 60 | 50 | 50 | |
| T9-20-03 | 3 | 108 | 90 | 75 | 50 | |
| T9-20-05 | 5 | 180 | 150 | 125 | 50 | |
| T9-20-10 | 10 | 360 | 300 | 250 | 50 | |
| T9-30-01 | 1 | 46 | 38 | 32 | 35 | |
| T9-30-02 | 2 | 92 | 76 | 64 | 35 | |
| T9-30-03 | 3 | 138 | 114 | 96 | 35 | |
| T9-30-05 | 5 | 230 | 190 | 160 | 35 | |
| T9-30-10 | 10 | 460 | 380 | 320 | 35 | |
T12 Series – 100V
Maximum heating element temperature: 120°C
Maximum cable surface temperature: approx. 90°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T12 Series – 100V
Maximum heating element temperature: 120°C
Maximum cable surface temperature: approx. 90°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W) | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T12-30-P01 | 1 | 49 | 43 | 37 | 35 | -30℃~120℃ |
| T12-30-P02 | 2 | 98 | 86 | 74 | ||
| T12-30-P03 | 3 | 147 | 129 | 111 | ||
| T12-30-P05 | 5 | 245 | 215 | 185 | ||
| T12-30-P10 | 10 | 490 | 430 | 370 | ||
T12 Series – 200V
Maximum heating element temperature: 120°C
Maximum cable surface temperature: approx. 90°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T12 Series – 200V
Maximum heating element temperature: 120°C
Maximum cable surface temperature: approx. 90°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W) | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T12-30-01 | 1 | 54 | 49 | 43 | 35 | -30℃~120℃ |
| T12-30-02 | 2 | 108 | 98 | 86 | ||
| T12-30-03 | 3 | 162 | 147 | 129 | ||
| T12-30-05 | 5 | 270 | 245 | 215 | ||
| T12-30-10 | 10 | 540 | 490 | 430 | ||
T6 bulk cable – For both 100V/200V
Maximum heating element temperature: 65°C
Maximum cable surface temperature: approx. 45°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T6 bulk cable – For both 100V/200V
Maximum heating element temperature: 65°C
Maximum cable surface temperature: approx. 45°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W)※ | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T6-10-M25 | 25 | 16/22 | 13/18 | 11/15 | 75 | -30℃~60℃ |
| T6-10-M50 | 50 | |||||
| T6-20-M25 | 25 | 20/27 | 16/23 | 12/18 | 50 | |
| T6-20-M50 | 50 | |||||
| T6-30-M25 | 25 | 29/35 | 23/29 | 18/23 | 35 | |
| T6-30-M50 | 50 | |||||
※Note: Values for 100 V and 200 V are listed together(100 V / 200 V).
T9 bulk cable – For both 100V/200V
Maximum heating element temperature: 95°C
Maximum cable surface temperature: approx. 70°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T9 bulk cable – For both 100V/200V
Maximum heating element temperature: 95°C
Maximum cable surface temperature: approx. 70°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W)※ | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T9-20-M25 | 25 | 19/36 | 18/30 | 17/25 | 50 | -10℃~100℃ |
| T9-20-M50 | 50 | |||||
| T9-30-M25 | 25 | 28/46 | 27/38 | 24/32 | 35 | |
| T9-30-M50 | 50 | |||||
※Note: Values for 100 V and 200 V are listed together(100 V / 200 V).
T12 bulk cable – For both 100V/200V
Maximum heating element temperature: 120°C
Maximum cable surface temperature: approx. 90°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
T12 bulk cable – For both 100V/200V
Maximum heating element temperature: 120°C
Maximum cable surface temperature: approx. 90°C
Note: The maximum cable surface temperature may vary depending on installation conditions.
| Article No. | Length (m) | Power(W)※ | Element pitch (mm) |
Allowable intermittent exposure temperature |
||
|---|---|---|---|---|---|---|
| Chamber temperature -20℃ |
Chamber temperature 0℃ |
Chamber temperature 20℃ |
||||
| T9-30-M25 | 25 | 49/54 | 43/49 | 37/43 | 35 | -30℃~120℃ |
| T9-30-M50 | 50 | |||||
※Note: Values for 100 V and 200 V are listed together(100 V / 200 V).